Multipoint data communication networks, such as Profibus, Modbus, and BACnet, typically require RS-485 dual-wire, half-duplex bus systems and four-wire, full-duplex bus system versatility. These systems can be extended to hundreds of meters in length and withstand large ground potential differences (GPD). These potential differences can exceed the common-mode voltage range of the transceiver and cause damage to the device. To eliminate GPD, we use an electrically isolated transceiver to isolate the control electronics of the bus node from the actual transceiver stage of the connected bus. Figure 1 shows a block diagram of a hybrid network using a 2-4 line converter.
Figure 1 2-4 line converter ensures versatility between half-duplex and full-duplex systems
In order to make the converter run independent of the data rate, we control the turn-on and turn-off of the converter driver and receiver through the logic state of the bus. The bus driver is at every bit interval, allowing the converter to operate independently of the signal data rate.
Simple control logic ensures that drivers D1 and D2 are only enabled by logic low activation of the opposite receiver (ie R1 or R2) output. Because there is a bus fault protection voltage of VFS > 200 mV at the receiver input, both receiver outputs are logic high during bus idle. The inverter gate reverses the logic high to a low state and enables the receiver while the driver is turned off.
In the half-to-full duplex direction (Figure 2: from left to right), the negative bus voltage at the R1 input activates drive D2 and uses a low state for the drive inputs. D2 responds by driving the transmission bus with a negative output voltage. When the bus voltage at the R1 input becomes positive, D2 immediately expires. However, its output is high because the fail-safe bias resistor RFS forms the bus voltage VFS.
(Note that during the entire run, the output of R2 is always high, ensuring that R1 remains active and D1 remains inactive.)
Figure 2 Half-duplex to full-duplex converter timing
In the full-to-half duplex direction (Figure 3: from right to left), the negative bus voltage at the R2 input activates driver D1 and applies a low state to the driver input. D1 responds by driving the two-wire bus with a negative output voltage. When the bus voltage at the R2 input becomes positive, D1 expires after a delay time. During this delay time, D1 uses a negative voltage to drive the bus before high impedance occurs to prevent switching transients at the R1 output.
We recommend that the minimum delay time generated by the RD∙CD time constant should be 1.3 times the maximum propagation delay of the driver to compensate for component values, inverter thresholds, and supply voltage tolerances. Under the given capacitance conditions, the required RD value can be determined by Equation 1:
Equation 1
Where tPLH-max is the maximum low-to-high propagation delay of driver D2, VIT+min is the minimum positive input threshold of the Schmitt-triggered inverter, and VCC-max is the maximum supply voltage.
After D1 fails, the bus voltage VFS formed by the fault protection bias resistor RFS has its output still high. When the bus voltage at the R2 input returns to negative, the CD is immediately activated due to the rapid discharge of the CD through the discharge diode DD. The timing diagram shown in Figure 3 shows a remote receiver on the half-duplex bus (here denoted by R) that converts the negative bus voltage to a low bit. A high bit consists of a low main drive positive bus voltage and a residual fault protection voltage VFS.
Figure 3 Converter timing from full duplex to half duplex
The transceiver stages of both converter ports require that the isolated power supplies VISO-1 and VISO-2 used be from a central 3.3V supply. Figure 5 is a schematic diagram of it. To avoid output peak requirements during no load conditions, each rectified output includes a minimum load resistor of 2 kΩ.
Figure 5 Isolated power supply design for VISO-1 and VISO-2
to sum up
A two-to-four-wire converter can be used to connect a single half-duplex transceiver or a complete half-duplex bus to a full-duplex bus. When connecting a two-to-four-wire converter to a full-duplex bus, it must be noted that the microcontroller of the master node changes its full-duplex to half-duplex transmission format when communicating with the converter node.
52 Jack,Professional Plastic 6p6c RJ45 ModularJack manufacturer is located in China, including Top Entry Rj45,6p6c Modular Connectors,RJ45 Connector Diagram, etc.
The RJ-45 interface can be used to connect the RJ-45 connector. It is suitable for the network constructed by twisted pair. This port is the most common port, which is generally provided by Ethernet hub. The number of hubs we usually talk about is the number of RJ-45 ports. The RJ-45 port of the hub can be directly connected to terminal devices such as computers and network printers, and can also be connected with other hub equipment and routers such as switches and hubs.