Control Cable with XLPE Insulation and PVC Sheath (KYJV)

Model NO.: KYJV
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC
Model: Control Cable
Brand: Hufei
Cores: 2-61
Certifcate: ISO9001-2008
Customized: Yes
MOQ: 1 M
Trademark: Hufei
Transport Package: Wooden Drum
Specification: ISO-9001
Origin: Shnghai
HS Code: 8544492100
Model NO.: KYJV
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC
Model: Control Cable
Brand: Hufei
Cores: 2-61
Certifcate: ISO9001-2008
Customized: Yes
MOQ: 1 M
Trademark: Hufei
Transport Package: Wooden Drum
Specification: ISO-9001
Origin: Shnghai
HS Code: 8544492100
Control Cbale with XLPE Insulation and PVC Sheath

It is used as connection cable of electric appliances and instruments for power distribution devices of rated voltage 600/1000V.


EXECUTICE STANDARD

enterprise standard(GB9330-88 for reference)

Working Condition

1.Temperature for installation& min.bending radius:
Preheating is unnecessary when ambient tempera-ture remains no lower than 0ºC .Installation is free from restriction by drop.And min,bending radius of cable is stipulated as follows:
a.It will be no less than 6 times that of cable OD for cable without armor.
b.It will be no less than 12 times that of cable OD for cable with armor or that with copper tape shielding.
c.It will be no less than 10 times tha of cable OD for soft cable with shielding structure.

2.Long-term working temperature of conductor is 90ºC.

3.Max temperature of cable conductoe is no more than 250ºC during short circuit 5s


Codes Meaning

Series code----------------------------------------------------K
Material Code
Copper conductor-------------------------------------------omitted
XLPE insulation-----------------------------------------------YJ
PVC Sheath-----------------------------------------------------V
PE sheath ------------------------------------------------------Y
Classified by Structure and Performance
Braided shielding--------------------------------------------P
Copper tape shielding--------------------------------------P2
Soft structure--------------------------------------------------R
Round type-----------------------------------------------------omitted
Flat type---------------------------------------------------------B


Type and Description
 
Type Name Section Area(mm2) No. of Core Application Site
KYJV Copper Conductor,XLPE Insulated
and Sheathed Control Cable
0.75 1.0 1.5 2.5 2-16 Permanent installation indoors,
in cable ditches or pipes
4 6 2-14
10 2-10
KYJVP Copper Conductor,XLPE Insulated and
Sheathed,Braiding Shielded Control
Cable
0.75 1.0 1.5 2.5 2-61 Permanent installation indoors,
in cable ditches or pipes where shielding is required
4 6 2-14
10 2-10
KYJVP2 Copper Conductor,XLPE Insulated
and Sheathed,Copper-tape Screened
Control Cable
0.75 1.0 1.5 2.5 4-10 Permanent installation indoors,
in cable ditches or pipes where shielding is required
4 6 7-61
10 4-10
KYJV22 Copper Conductor,XLPE Insulated and
Sheathed,Steel tape Armored Control
Cable
0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,
in cable ditches,Be able to withstand stronger e
xternal mechanical force
4 6 4-14
10 4-14
KYJVR Copper Conductor,XLPE Insulated and
Sheathed,Flexible Control Cable
0.5-2.5 4-61 Installation indoors where flexibility and
movability are required
KYJVRP Copper Conductor,XLPE Insulated and
Sheathed,Braiding shielded Flexible
Control Cable
0.5 0.75 1.0 4-61 Installation indoors where flexibility shielding and
movability are required

The figure of cable structure
Control Cable with XLPE Insulation and PVC Sheath (KYJV)

Technical Parameter
1.DC resistance of finished cable conductor at 20ºC 
Item Unit Technical indices
DC resitance of conductor at 20ºC Ω/km cross section area
mm2
0.75 1.0 1.5 2.5 4 6 10
Category
A,B
24.5 18.1 12.2 7.41 4.61 3.08 1.83
category R 26.0 19.5 13.3 7.98 / / /

2.Finisehed cable should bear A.C. voltage of 3.5KV under power frequency for 5 min without puncture of insu-lation.

3.Insulated resistance of cable:
It is no less than1.0MΩ.km AT MAX.Rated working temperature.

4.Control cable with XLPE insulation has good fea-tures of heat resistance,freezing resistance,chemistry resistance,insulated resistance and long lifetime com-pared with control cable with PVC insualtion.

External Dimension of Common Type
Control Cable with XLPE Insulation and PVC Sheath (KYJV)

  Control Cbale with XLPE Insulation and PVC Sheath

It is used as connection cable of electric appliances and instruments for power distribution devices of rated voltage 600/1000V.


EXECUTICE STANDARD

enterprise standard(GB9330-88 for reference)

Working Condition

1.Temperature for installation& min.bending radius:
Preheating is unnecessary when ambient tempera-ture remains no lower than 0ºC .Installation is free from restriction by drop.And min,bending radius of cable is stipulated as follows:
a.It will be no less than 6 times that of cable OD for cable without armor.
b.It will be no less than 12 times that of cable OD for cable with armor or that with copper tape shielding.
c.It will be no less than 10 times tha of cable OD for soft cable with shielding structure.

2.Long-term working temperature of conductor is 90ºC.

3.Max temperature of cable conductoe is no more than 250ºC during short circuit 5s


Codes Meaning

Series code----------------------------------------------------K
Material Code
Copper conductor-------------------------------------------omitted
XLPE insulation-----------------------------------------------YJ
PVC Sheath-----------------------------------------------------V
PE sheath ------------------------------------------------------Y
Classified by Structure and Performance
Braided shielding--------------------------------------------P
Copper tape shielding--------------------------------------P2
Soft structure--------------------------------------------------R
Round type-----------------------------------------------------omitted
Flat type---------------------------------------------------------B


Type and Description
 
Type Name Section Area(mm2) No. of Core Application Site
KYJV Copper Conductor,XLPE Insulated
and Sheathed Control Cable
0.75 1.0 1.5 2.5 2-16 Permanent installation indoors,
in cable ditches or pipes
4 6 2-14
10 2-10
KYJVP Copper Conductor,XLPE Insulated and
Sheathed,Braiding Shielded Control
Cable
0.75 1.0 1.5 2.5 2-61 Permanent installation indoors,
in cable ditches or pipes where shielding is required
4 6 2-14
10 2-10
KYJVP2 Copper Conductor,XLPE Insulated
and Sheathed,Copper-tape Screened
Control Cable
0.75 1.0 1.5 2.5 4-10 Permanent installation indoors,
in cable ditches or pipes where shielding is required
4 6 7-61
10 4-10
KYJV22 Copper Conductor,XLPE Insulated and
Sheathed,Steel tape Armored Control
Cable
0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,
in cable ditches,Be able to withstand stronger e
xternal mechanical force
4 6 4-14
10 4-14
KYJVR Copper Conductor,XLPE Insulated and
Sheathed,Flexible Control Cable
0.5-2.5 4-61 Installation indoors where flexibility and
movability are required
KYJVRP Copper Conductor,XLPE Insulated and
Sheathed,Braiding shielded Flexible
Control Cable
0.5 0.75 1.0 4-61 Installation indoors where flexibility shielding and
movability are required

The figure of cable structure
Control Cable with XLPE Insulation and PVC Sheath (KYJV)

Technical Parameter
1.DC resistance of finished cable conductor at 20ºC 
Item Unit Technical indices
DC resitance of conductor at 20ºC Ω/km cross section area
mm2
0.75 1.0 1.5 2.5 4 6 10
Category
A,B
24.5 18.1 12.2 7.41 4.61 3.08 1.83
category R 26.0 19.5 13.3 7.98 / / /

2.Finisehed cable should bear A.C. voltage of 3.5KV under power frequency for 5 min without puncture of insu-lation.

3.Insulated resistance of cable:
It is no less than1.0MΩ.km AT MAX.Rated working temperature.

4.Control cable with XLPE insulation has good fea-tures of heat resistance,freezing resistance,chemistry resistance,insulated resistance and long lifetime com-pared with control cable with PVC insualtion.

External Dimension of Common Type
Control Cable with XLPE Insulation and PVC Sheath (KYJV)

 

Automobile Connector Socket

Automobile Connector Socket,Automotive Wiring Harness Plugs,Automotive New Energy Connectors,Automotive Waterproof Connectors

Shenzhen huaxunde Technology CO.,Ltd. , https://www.huaxundekj.com